J Physiol Wellcome Trust-funded researchers
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 268, Issue 1 pp 151-176
Copyright © 1977 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Agarwal, G. C.
Right arrow Articles by Gottlieb, G. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Agarwal, G. C.
Right arrow Articles by Gottlieb, G. L.

Oscillation of the human ankle joint in response to applied sinusoidal torque on the foot

Gyan C. Agarwal and Gerald L. Gottlieb

Department of Physiology, Rush—Presbyterian—St Luke's Medical Center, Chicago, Illinois 60612

College of Engineering, University of Illinois at Chicago Circle, Chicago, Illinois 60680, U.S.A.

1. Low-frequency (3-30 Hz) oscillatory rotation of the ankle joint in plantarflexion—dorsiflexion was generated with a torque motor. Torque, rotation about the ankle and electromyograms (e.m.g.s) for the gastrocnemius—soleus and the anterior tibial muscles were recorded.

2. Fourier coefficients at each drive frequency were used to calculate the effective compliance (ratio of rotation and torque). The compliance has a sharp resonance when tonic, voluntary muscle activity is present.

3. The resonant frequency of compliance is between 3 and 8 Hz. The location of the resonant frequency and the magnitude of the compliance at resonance depend upon both the degree of tonic muscle activity and the amplitude of the driving torque. The resonant frequency increases with increasing tonic activity.

4. With tonic muscle activity, the compliance in the frequency range below resonance increases with increasing amplitudes of driving torque.

5. The e.m.g., when evoked by the rhythmic stretch, lags the start of stretching by between 50 and 70 msec.

6. When tonic muscle activity is present, the resonant frequency of the stretch reflex is between 5 and 6·5 Hz.

7. Following the start of driven oscillation at frequencies near resonance, slowly increasing amplitudes of angular rotation (to a limit) are observed.

8. Distortion (from the sinusoidal wave shape) of angular rotation is frequently observed with drive frequencies between 8 and 12 Hz during which there sometimes occur spontaneous recurrences of oscillation at the drive frequency. For the angular rotation, a significant portion of the power may be in subharmonic frequency components of the drive frequency when that frequency is between 8 and 12 Hz.

9. Self-sustaining oscillation (clonus) near the resonant frequency of the compliance is sometimes observed after the modulation signal to the motor is turned off. This is most often seen when the gastrocnemius—soleus muscles are fatigued. Clonus may be evoked by driven oscillation at any frequency.

10. The hypothesis that physiological tremor, which occurs between 8 and 12 Hz, is a consequence of stretch reflex servo properties seems to be at odds with the observations of resonance in the compliance and of self-generated clonus both occurring in the 5-8 Hz region.




This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
D. A. Kistemaker, A. J. Van Soest, and M. F. Bobbert
Equilibrium Point Control Cannot be Refuted by Experimental Reconstruction of Equilibrium Point Trajectories
J Neurophysiol, September 1, 2007; 98(3): 1075 - 1082.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
D. C. Lin and W. Z. Rymer
Damping Actions of the Neuromuscular System With Inertial Loads: Soleus Muscle of the Decerebrate Cat
J Neurophysiol, February 1, 2000; 83(2): 652 - 658.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. T. Farley, H. H. P. Houdijk, C. Van Strien, and M. Louie
Mechanism of leg stiffness adjustment for hopping on surfaces of different stiffnesses
J Appl Physiol, September 1, 1998; 85(3): 1044 - 1055.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 The Physiological Society.