J Physiol Vol 272, Issue 2 pp 415-433
Copyright © 1977 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferrington, D. G.
Right arrow Articles by Rowe, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferrington, D. G.
Right arrow Articles by Rowe, M.

Human tactile detection thresholds: modification by inputs from specific tactile receptor classes

D. G. Ferrington, B. S. Nail and Mark Rowe

1. Human detection thresholds for a vibratory stimulus applied to the volar surface of the index finger were examined under conditions where afferents from specific tactile receptor classes were simultaneously activated from the thenar eminence. The experiments were designed to test whether stimuli which have been shown previously to induce afferent inhibition of `tactile' neurones in the cuneate nucleus of the cat could modify human subjective performance in a tactile detection task. Conditioning stimuli to the thenar eminence were usually of three forms; steady indentation to engage slowly adapting tactile receptors; 300 Hz vibration to engage Pacinian corpuscles; and 30 Hz vibration to engage the intradermal, rapidly adapting tactile receptors which are thought to be Meissner's corpuscles.

2. In ten subjects the mean detection threshold for a 30 Hz test stimulus in the absence of conditioning stimulation was 8·6 ± 1·0 µm (S.E.). Detection thresholds were increased substantially in the presence of a 300 Hz, 100 µm conditioning stimulus (mean increase 11·1 ± 2·0 µm), whereas minor or insignificant effects were seen with conditioning stimuli consisting of (a) 30 Hz, 100 µm (mean increase 1·4 ± 0·8 µm), (b) steady indentation, 1·5 mm in amplitude (mean increase 1·3 ± 0·7 µm) or (c) 300 Hz, 100 µm to the contralateral thenar eminence (mean increase 0·4 ± 0·5 µm).

3. The 300 Hz conditioning stimulus to the ipsilateral thenar eminence caused a marked increase in detection thresholds at all test stimulus frequencies over the range 10-450 Hz. The effects of the conditioning stimulation therefore operated on inputs from Pacinian corpuscles, which are responsible for vibration detection at 80-450 Hz, and on inputs from the intradermal, rapidly adapting receptors which are responsible for vibration detection at 10-80 Hz.

4. The band width of conditioning vibratory frequencies which was effective at amplitudes of 100 µm in bringing about increases in detection threshold extended from 50-80 Hz to 300 Hz, the maximum tested.

5. Whereas amplitudes of 1-2 µm produced clear increases in detection thresholds with conditioning stimuli of 300 Hz, amplitudes of > 200 µm were needed at 30 Hz.

6. The observed elevations in detection threshold are consistent with an afferent-induced inhibitory action exerted at synaptic relays of the sensory pathway by tactile inputs arising exclusively or predominantly from Pacinian corpuscles.




This article has been cited by other articles:


Home page
J. Physiol.Home page
N. S. Weerakkody, D. A. Mahns, J. L. Taylor, and S. C. Gandevia
Impairment of human proprioception by high-frequency cutaneous vibration
J. Physiol., June 15, 2007; 581(3): 971 - 980.