J Physiol Society Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 349 pp 27-42
Copyright © 1984 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knight, A D
Right arrow Articles by Levick, J R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knight, A D
Right arrow Articles by Levick, J R

The influence of blood pressure on trans-synovial flow in the rabbit.

A D Knight and J R Levick

Fluid exchange across the synovium lining the cavity of extended knees was studied in twenty rabbit hindquarters. The isolated hindquarters were perfused with blood from an extracorporeal pump-oxygenator system at controlled arterial pressure (PA) and venous pressure (PV). Intra-articular pressure (PJ) was set at 18 cmH2O in most experiments. The rate of trans-synovial absorption of Krebs solution (QS), measured by a drop-counter, was a negative linear function of PA (70-160 mmHg) and of PV (2-42 cmH2O). The sensitivity of exchange to venous pressure ( dQS / dPV , mean -0.25 +/- 0.03 microliter min-1 mmHg-1) was greater than its sensitivity to arterial pressure ( dQS /dPA, mean -0.17 +/- 0.02 microliter min-1 mmHg-1). The ratio of the slopes, ( dQS / dPV )/( dQS /dPA), indicated the pre- to post-capillary vascular resistance ratio. From this ratio and PA, PV, synovial capillary pressures PC were calculated by the equation of Pappenheimer & Soto - Rivera (1948). Trans-synovial absorption rate was a negative linear function of PC. This observation supports the application to the synovial cavity of Starling's hypothesis for fluid exchange between interstitial spaces and plasma (Starling, 1896). The slope dQS /dPC equalled the net hydraulic conductance of the blood-joint barrier (synovium plus capillary endothelium), and averaged -0.425 +/- 0.025 microliter min-1 mmHg-1 at PJ = 18 cmH2O. When PJ was subatmospheric, as is common in extended normal joints, fluid exchange (measured indirectly as dPJ /dt) was only approximately 1/4 as sensitive to blood pressure as at PJ = 18 cmH2O. This observation supported the view that the conductance of the blood-joint barrier depends on PJ.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 The Physiological Society.