J Physiol Society Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 353 pp 265-285
Copyright © 1984 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lakie, M
Right arrow Articles by Wright, G W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lakie, M
Right arrow Articles by Wright, G W

Resonance at the wrist demonstrated by the use of a torque motor: an instrumental analysis of muscle tone in man.

M Lakie, E G Walsh and G W Wright

The resonance of the relaxed wrist for flexion-extension movements in the horizontal plane has been investigated by using rhythmic torques generated by a printed motor. In the normal subject the resonant frequency of the wrist is ca. 2 Hz unless the torque is reduced below a certain critical value when the system is no longer linear and the resonant frequency rises. This critical torque level, and the damping are both less in women than men. The resonant frequency is uninfluenced by surgical anaesthesia. With added bias the increase of resonant frequency at low torques still occurs although the hand is now oscillating about a displaced mean position. It follows that the stiffening implied by this elevation of resonant frequency for small movements is neither the result of pre-stressing of the muscles nor of reflex activity. With velocity feed-back of appropriate polarity the system will oscillate spontaneously at its resonant frequency. If the peak driving torque is progressively reduced the resonant frequency increases abruptly, indicating that the system has stiffened. Perturbations delivered to the wrist may reduce its stiffness. The postural system is thixotropic with a 'memory time' of 1-2 s. The resonant frequency is elevated in voluntary stiffening.




This article has been cited by other articles:


Home page
Biophys. JHome page
K. S. Campbell and M. Lakie
Response to Bianco et al.: Interaction Forces between F-actin and Titin PEVK Domain Measured with Optical Tweezers
Biophys. J., January 1, 2008; 94(1): 327 - 328.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
I. D. Loram, C. N. Maganaris, and M. Lakie
The passive, human calf muscles in relation to standing: the non-linear decrease from short range to long range stiffness
J. Physiol., October 15, 2007; 584(2): 661 - 675.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
I. D. Loram, C. N. Maganaris, and M. Lakie
The passive, human calf muscles in relation to standing: the short range stiffness lies in the contractile component
J. Physiol., October 15, 2007; 584(2): 677 - 692.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Izumizaki, M. Iwase, Y. Ohshima, and I. Homma
Acute effects of thixotropy conditioning of inspiratory muscles on end-expiratory chest wall and lung volumes in normal humans
J Appl Physiol, July 1, 2006; 101(1): 298 - 306.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
I. Homma and K.-E. Hagbarth
Thixotropy of rib cage respiratory muscles in normal subjects
J Appl Physiol, November 1, 2000; 89(5): 1753 - 1758.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 The Physiological Society.