J Physiol Society Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 411 pp 85-96
Copyright © 1989 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jacobi, M S
Right arrow Articles by Saunders, K B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jacobi, M S
Right arrow Articles by Saunders, K B

Transient, steady-state and rebreathing responses to carbon dioxide in man, at rest and during light exercise.

M S Jacobi, C P Patil and K B Saunders

Department of Medicine I, St George's Hospital Medical School, London.

1. The transient ventilatory response to CO2, measured using short pulses at constant inflow, was compared with the steady-state response at rest and during exercise at 50 W, and with the rebreathing response at rest, in nine healthy subjects. At rest CO2 was given at flow rates of 0.2 and 0.4 l min-1 and during exercise, to compensate for the smaller inhaled CO2 fraction as ventilation increased, at flow rates of 0.4 and 0.8 l min-1. 2. We calculated two indexes of gain for the transient response: the ratio of the peaks of the ventilation and PCO2 pulses, and the ratio of their integrals. 3. The steady-state response was greater than the transient response at rest and during exercise, but there was no correlation between the two. The rebreathing response was greater than both. Both the transient and the steady-state responses were greater during exercise than at rest. 4. To assess alinearity, the steady-state responses to the two CO2 flow rates were compared. At rest, there was no significant difference. During exercise, the response was greater to 0.4 than 0.8 l min-1, indicating alinearity concave downwards. 5. We conclude that the transient response as we calculate it is not representative of steady-state gain, and that the CO2 response in light exercise is steeper, and concave downwards in shape. The rebreathing technique overestimates CO2 sensitivity near the control point.




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
Y. Fukuoka, M. Endo, Y. Oishi, and H. Ikegami
Chemoreflex Drive and the Dynamics of Ventilation and Gas Exchange during Exercise at Hypoxia
Am. J. Respir. Crit. Care Med., November 1, 2003; 168(9): 1115 - 1122.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
H.A.K. Browne, L. Adams, A.K. Simonds, and M.J. Morrell
Ageing does not influence the sleep-related decrease in the hypercapnic ventilatory response
Eur. Respir. J., March 1, 2003; 21(3): 523 - 529.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 The Physiological Society.