J Physiol Society Meetings
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 415 pp 459-475
Copyright © 1989 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by di Prampero, P E
Right arrow Articles by Lafortuna, C L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by di Prampero, P E
Right arrow Articles by Lafortuna, C L

Breath-by-breath estimate of alveolar gas transfer variability in man at rest and during exercise.

P E di Prampero and C L Lafortuna

Département de Physiologie, C.M.U., Genève, Switzerland.

1. Breath-by-breath (BB) oxygen and carbon dioxide transfer (VO2 and VCO2) at the mouth, together with respiratory pattern, were determined over sequences of 100 consecutive breaths in six subjects at rest and during cycloergometric exercise (75 W). 2. BBVO2 and VCO2 at alveolar level were calculated taking the changes of pulmonary gas stores throughout each single ith breath into account. This requires knowledge of the alveolar volume at the beginning of the breath (VA.i-1), which cannot be directly measured on a BB basis at present. Therefore a constant nominal value, ranging from 0 to 5 l, was attributed to VA,i-1. 3. It was found that: (i) all nominal VA.i-1 values employed for the estimate of steady-state alveolar gas exchange yield the same average value but greatly reduce BB variability with respect to gas exchange as determined at the mouth; (ii) no unequivocal criterion was identified to select the appropriate VA.i-1 value; and (iii) the apparent kinetics of alveolar VO2 after work onset may be influenced by the VA.i-1 value selected for the calculation, and by the change in lung volume at the onset of exercise. 4. It was concluded that: (i) as long as VA.i-1 cannot be measured for each single breath, 'true' alveolar gas exchange remains elusive; hence, (ii) it is not possible to establish the extent to which the alveolar gas exchange variability depends on physiological phenomena using available methods.




This article has been cited by other articles:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
F. Lador, M. Azabji Kenfack, C. Moia, M. Cautero, D. R. Morel, C. Capelli, and G. Ferretti
Simultaneous determination of the kinetics of cardiac output, systemic O2 delivery, and lung O2 uptake at exercise onset in men
Am J Physiol Regulatory Integrative Comp Physiol, April 1, 2006; 290(4): R1071 - R1079.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Aliverti, B. Kayser, and P. T. Macklem
Breath-by-breath assessment of alveolar gas stores and exchange
J Appl Physiol, April 1, 2004; 96(4): 1464 - 1469.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Busso and P. A. Robbins
Evaluation of estimates of alveolar gas exchange by using a tidally ventilated nonhomogenous lung model
J Appl Physiol, June 1, 1997; 82(6): 1963 - 1971.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 The Physiological Society.