J Physiol Wellcome Trust-funded researchers
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 456 pp 71-83
Copyright © 1992 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berkenbosch, A
Right arrow Articles by Olievier, I C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berkenbosch, A
Right arrow Articles by Olievier, I C

The ventilatory response to CO2 of the peripheral and central chemoreflex loop before and after sustained hypoxia in man.

A Berkenbosch, A Dahan, J DeGoede and I C Olievier

Department of Physiology, University of Leiden, The Netherlands.

1. The ventilatory response to sustained hypoxia is characterized by a fast increase due to the peripheral chemoreceptors followed by a slow decline. The mechanism of this decline is unknown. 2. To investigate the characteristics of the ventilatory response to sustained hypoxia ten healthy subjects were exposed to two consecutive periods of isocapnic hypoxia (arterial saturation 78%) separated by a 5 min exposure to isocapnic normoxia. 3. The acute hypoxic response to the second exposure to hypoxia (mean increase in ventilation +/- S.E.M., 7.2 +/- 0.8 l min-1) was significantly depressed (P = 0.04) compared to the first one (9.5 +/- 1.3 l min-1). 4. To investigate whether this depression was due to central or peripheral effects or both we measured, in the same ten subjects, the normoxic ventilatory response to CO2 before and after a period of 25 min of hypoxia using the technique of dynamic end-tidal forcing. 5. Each response was separated into a fast peripheral and slow central component characterized by a CO2 sensitivity, time constant, time delay and an off-set. 6. A total of thirty-six prehypoxic and thirty posthypoxic responses were analysed. The ventilatory CO2 sensitivities of the peripheral and central chemoreflex loops and the overall off-set (apnoeic threshold) after 25 min of hypoxia were somewhat larger than their prehypoxic values, but this effect was not significant. 7. We argue that the hypoxic ventilatory decline in man is due to a change in the off-set of the peripheral chemoreflex loop.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. J. Pandit, D. Sjogren, S. G. E. Lindahl, and A. Sollevi
Hypoxic ventilatory response: the effects of CO2 and of sustained hypoxia.
Anesth. Analg., March 1, 1999; 88(3): 695 - 696.
[Full Text] [PDF]