J Physiol Society Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Vol 492, Issue Pt 1 pp 39-52
Copyright © 1996 by The Physiological Society
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neal, C R
Right arrow Articles by Michel, C C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neal, C R
Right arrow Articles by Michel, C C

Openings in frog microvascular endothelium induced by high intravascular pressures.

C R Neal and C C Michel

Department of Physiology and Biophysics, Imperial College School of Medicine at St Mary's, London, UK.

1. We have investigated the effects of microvascular pressures, high enough to rupture the vessel wall, upon the ultrastructure and permeability of mesenteric capillaries in pithed frogs. 2. The vessels were perfused via micropipettes with Ringer solutions containing bovine serum albumin (1 mg ml-1) and a few human red cells. After a perfused section of vessel had been closed downstream, pressure (applied via the micropipette) was raised in a series of steps of 10 mmHg, each lasting approximately 10 s, until the vessel ruptured. Fluid filtration through the vessel wall prior to rupture was estimated from the movements of the red cells. 3. Seven vessels were fixed in glutaraldehyde immediately after rupture and prepared for electron microscopy. The electron micrographs revealed openings in the vessel walls and thirty-six of these gaps were completely defined in runs of serial sections made on four of the vessels. Twenty-nine of these gaps passed through the endothelial cells (transcellular) and seven were intercellular. 4. The pressure at which a vessel ruptured, Pb, was measured in twenty-nine vessels and had a mean +/- S.E.M. value of 79.6 +/- 5.0 cmH2O. In ten of these vessels, which had a mean +/- S.E.M. Pb of 84.2 +/- 6.5 cmH2O, microvascular pressure was lowered immediately after the initial rupture and the vessel perfused at a pressure of 20 cmH2O. Pb was then remeasured and found to be 69.9 +/- 8.4 cmH2O, which was not significantly different from its initial value. 5. Hydraulic permeability (Lp) was measured in six vessels over the range of 15-30 cmH2O before and 10 min after the vessel wall ruptured at high pressure. Mean values were 5.5 x 10(-7) and 4.0 x 10(-7) cms-1 cmH2O-1 and were not significantly different. 6. At pressures equal to and 10 mmHg below Pb, small short-lived increases in filtration rate were observed. It is suggested that these may correspond to the increased permeability to fluid and macromolecules observed at high microvascular pressures in intact capillary beds.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Lindenberger and T. Lanne
Decreased capillary filtration but maintained venous compliance in the lower limb of aging women
Am J Physiol Heart Circ Physiol, December 1, 2007; 293(6): H3568 - H3574.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
J. N. Maina and J. B. West
Thin and Strong! The Bioengineering Dilemma in the Structural and Functional Design of the Blood-Gas Barrier
Physiol Rev, July 1, 2005; 85(3): 811 - 844.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
P. Bartsch, H. Mairbaurl, M. Maggiorini, and E. R. Swenson
Physiological aspects of high-altitude pulmonary edema
J Appl Physiol, March 1, 2005; 98(3): 1101 - 1110.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 The Physiological Society.