J Physiol Wellcome Trust-funded researchers
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Volume 547, Number 2, 621-628, March 1, 2003 DOI: 10.1113/jphysiol.2002.028795
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
547/2/621    most recent
2002.028795v1
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Takeda, T.
Right arrow Articles by Mittal, R. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takeda, T.
Right arrow Articles by Mittal, R. K.
J Physiol (2003), 547.2, pp. 621-628
© Copyright 2003 D 2003 The Physiological Society
DOI: 10.1113/jphysiol.2002.028795

Effect of atropine on the biomechanical properties of the oesophageal wall in humans

Torahiko Takeda*, Ghassan Kassab†, Jianmin Liu*, Toshinaga Nabae* and Ravinder K. Mittal*

*Division of Gastroenterology, VA Medical Center, University of California, San Diego, CA 92161 and †Department of Biomedical Engineering, University of California, Irvine, CA 92697, USA

Recently, we reported a novel ultrasound technique to assess biomechanical properties of the oesophagus in human subjects. In the present study, we use the technique, in combination with atropine, to determine the active and passive biomechanical properties of the oesophagus in normal healthy humans. A manometric catheter equipped with a high-compliance bag and a high-frequency intraluminal ultrasonography probe was used to record pressure and oesophageal geometry. Oesophageal distensions with either isovolumic (5-20 ml water) or with isobaric (10-60 mmHg) technique were performed. Intra-bag pressure and ultrasound images of the oesophagus were recorded simultaneously. Following injection of atropine (15 µg kg-1, I.V.), the oesophageal distensions were repeated. The oesophageal wall compliance, circumferential wall tension, stress, strain and elastic modulus were calculated. Atropine resulted in an increase in the oesophageal wall compliance during isobaric distension, but no change in compliance was observed during isovolumic distension. The stress-strain relationship was found to be linear during both types of distension, before as well as after atropine. The Young's modulus, which is the slope of a linear stress-strain relationship, was significantly higher after atropine in the isovolumic study but not in the isobaric study. The stress-strain relationship of the active component (muscle contraction) was different during isovolumic and isobaric distensions but the passive components were similar. The passive and active stress-strain relationships of the human oesophagus resemble those of other soft biological tissues. Furthermore, the method of oesophageal distension has significant influence on the active but not the passive biomechanical properties due to a strain-rate effect.



This article has been cited by other articles:


Home page
Am. J. Physiol. Gastrointest. Liver Physiol.Home page
B. S. Padda, S.-A. Jung, D. Pretorius, C. W. Nager, D. Den-Boer, and R. K. Mittal
Effects of pelvic floor muscle contraction on anal canal pressure
Am J Physiol Gastrointest Liver Physiol, February 1, 2007; 292(2): G565 - G571.