J Physiol Society Meetings
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Volume 555, Number 3, 805-814, March 15, 2004 DOI: 10.1113/jphysiol.2003.057919
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
555/3/805    most recent
jphysiol.2003.057919v1
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moore, J. P.
Right arrow Articles by Drinkhill, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moore, J. P.
Right arrow Articles by Drinkhill, M. J.

Pulmonary arterial distension and vagal afferent nerve activity in anaesthetized dogs

Jonathan P. Moore, Roger Hainsworth and Mark J. Drinkhill

Institute for Cardiovascular Research, The School of Medicine, University of Leeds, Leed LS2 9JT, UK

Distension of the main pulmonary artery and its bifurcation are known to result in a reflex vasoconstriction and increased respiratory drive; however, these responses are observed at abnormally high distending pressures. In this study we recorded afferent activity from pulmonary arterial baroreceptors to investigate their stimulus–response characteristics and to determine whether they are influenced by physiological changes in intrathoracic pressure. In chloralose-anaesthetized dogs, a cardiopulmonary bypass was established, the pulmonary trunk and its main branches were vascularly isolated and perfused with venous blood at pulstatile pressures designed to simulate the normal pulmonary arterial pressure waveform. Afferent slips of a cervical vagus were dissected and nerve fibres identified that displayed discharge patterns with characteristics expected from pulmonary arterial baroreceptors. Recordings were obtained with (a) chest open (b) chest closed and resealed, and (c) with phasic negative intrathoracic pressures in the resealed chest. Pressure–discharge characteristics obtained in the open-chest animals indicated that the threshold pulmonary pressure (corresponding to 5% of the overall response) was 17.1 ± 2.9 and the inflexion point of the curve was 29.2 ± 3.3 mmHg (mean ±S.E.M). In closed-chest animals the threshold and inflexion pressures were reduced to 12.0 ± 1.7 and 20.7 ± 1.8 mmHg. Application of phasic negative intrathoracic pressures further reduced the threshold and inflexion pressures to 9.5 ± 1.2 mmHg (P < 0.05 vs. open) and 14.7 ± 0.8 mmHg (P < 0.003 vs. open and P < 0.02 vs. atmospheric). These results indicate that under physiological conditions, with closed-chest and phasic negative intrathoracic pressure changes similar to those associated with normal breathing, activity from pulmonary baroreceptors is obtained at physiological pulmonary arterial pressures in intact animals.

(Received 19 November 2003; accepted after revision 16 January 2004; first published online 23 January 2004)
Corresponding author M. J. Drinkhill: Institute for Cardiovascular Research, The School of Medicine, University of Leeds, Leeds LS2 9JT, UK. Email: cvsmjd{at}leeds.ac.uk







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 The Physiological Society.