J Physiol Society Meetings
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Volume 555, Number 3, 815-824, March 15, 2004 DOI: 10.1113/jphysiol.2003.057968
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
555/3/815    most recent
jphysiol.2003.057968v1
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moore, J. P.
Right arrow Articles by Drinkhill, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moore, J. P.
Right arrow Articles by Drinkhill, M. J.

Phasic negative intrathoracic pressures enhance the vascular responses to stimulation of pulmonary arterial baroreceptors in closed-chest anaesthetized dogs

Jonathan P. Moore, Roger Hainsworth and Mark J. Drinkhill

Institute for Cardiovascular Research, The School of Medicine, University of Leeds, Leeds LS2 9JT, UK

We investigated whether the reflex responses to stimulation of pulmonary arterial baroreceptors were altered by intrathoracic pressure changes similar to those encountered during normal breathing. Dogs were anaesthetized with {alpha}-chloralose, a cardiopulmonary bypass was established, and the pulmonary trunk and its main branches as far as the first lobar arteries were vascularly isolated and perfused with venous blood. The chest was closed following connection to the perfusion circuit and pressures distending the aortic arch, carotid sinus and coronary artery baroreceptors were controlled. Changes in the descending aortic (systemic) perfusion pressure (SPP; flow constant) were used to assess changes in systemic vascular resistance. Values of SPP were plotted against mean pulmonary arterial pressure (PAP) and sigmoid functions applied. From these curves we derived the threshold pressures (corresponding to 5% of the overall response of SPP), the maximum slopes (equivalent to peak gain) and the corresponding PAP (equivalent to ‘set point’). Stimulus–response curves were compared between data obtained with intrathoracic pressure at atmospheric and with a phasic intrathoracic pressure ranging from atmospheric to around -10 mmHg (18 cycles min-1). Results were obtained from seven dogs and are given as means ±S.E.M. Compared to the values obtained when intrathoracic pressure was at atmospheric, the phasic intrathoracic pressure decreased the pulmonary arterial threshold pressure in five dogs; average change from 28.4 ± 5.9 to 19.3 ± 5.9 mmHg (P > 0.05). The inflexion pressure was significantly reduced from 37.8 ± 4.8 to 27.4 ± 4.0 mmHg (P < 0.03), but the slopes of the curves were not consistently changed. These results have shown that a phasic intrathoracic pressure, which simulates respiratory oscillations, displaces the stimulus–response curve of the pulmonary arterial baroreceptors to lower pressures so that it lies within a physiological range of pressures.

(Received 19 November 2003; accepted after revision 5 January 2004; first published online 14 January 2004)
Corresponding author M. J. Drinkhill: Institute for Cardiovascular Research, School of Medicine, University of Leeds, Leeds LS2 9JT, UK. Email: cvsmjd{at}leeds.ac.uk







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 The Physiological Society.