|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
NEUROSCIENCE |
1 Dipartimento di Scienze Fisiologiche e Farmacologiche and Istituto Naz. Fisica della Materia, Università di Pavia, Via Forlanini 6, 27100 Pavia, Italy
| Abstract |
|---|
|
|
|---|
(Received 3 April 2006;
accepted after revision 5 May 2006;
first published online 11 May 2006)
Corresponding author L. Forti: Dipartimento di Scienze Fisiologiche e Farmacologiche, Università di Pavia, Via Forlanini 6, 27100 Pavia, Italy. Email: lforti{at}unipv.it
| Introduction |
|---|
|
|
|---|
50 Hz, Edgley & Lidierth, 1987; monkey: 1080 Hz, Miles et al. 1980) and anaesthetized animals (rat: 2 to
30 Hz, Schulman & Bloom, 1981; Vos et al. 1999). An interesting observation is that the granular layer of awake animals during states of quiet attentiveness shows a population oscillatory activity at 78 Hz (rat; Hartmann & Bower, 1998) or 1518 Hz (monkey; Pellerin & Lamarre, 1997). This raises the question as to whether GoC rhythmicity is driven by network oscillations or is due to intrinsic pacemaking. Answering this question is critical in view of the role played by neuronal excitability in determining network behaviours (Llinás, 1988).
The observation of GoC spontaneous discharge in cerebellar slices (
3 Hz, rat, Dieudonné, 1998; 520 Hz, turtle, Midtgaard, 1992) suggests that GoCs could be autorhythmic. Autorhythmicity usually requires the interplay of at least two voltage-dependent mechanisms, one causing feedforward depolarization, and the other delayed feedback repolarization (Wang & Rinzel, 1999; Hutcheon & Yarom, 2000). In low-frequency (110 Hz) pacemaker neurons, subthreshold Na+ currents (INa,sub) are generally found to contribute to pacemaker depolarization (Pennartz et al. 1997; Feigenspan et al. 1998; Bevan & Wilson, 1999; Bennett et al. 2000; Beurrier et al. 2000; Wilson & Callaway, 2000; Taddese & Bean, 2002; Do & Bean, 2003; Jackson et al. 2004 and references therein). A contribution to this depolarization is also given, in some neuronal types, by the hyperpolarization-activated current Ih (Maccaferri & McBain, 1996; Bennett et al. 2000; Neuhoff et al. 2002; Funahashi et al. 2003; Chan et al. 2004) and by voltage-dependent Ca2+ currents with low activation threshold (Wilson & Callaway, 2000; Jackson et al. 2004; Pignatelli et al. 2005). Among feedback voltage-dependent mechanisms, a number of slow K+ currents may contribute to interspike repolarization on a time scale compatible with slow pacemaking. Apamin-sensitive Ca2+-dependent K+ currents (Iapa) can regulate firing frequency and precision in several pacemaker neurons (reviewed in Stocker, 2004). Given its slow activation just below action potential (AP) threshold and its lack of inactivation (Brown & Adams, 1980; Brown & Yu, 2000), the M-type K+ current (IM) is also expected to regulate the interspike trajectory. Although IM functional properties in native neurons have been mainly studied in non-pacemaker cells (reviewed in Brown & Yu, 2000), immunocytochemical data suggest that KCNQ2, a member of the KCNQ (Kv7) family, which is thought to generate IM (Wang et al. 1998; Brown & Yu, 2000; Jentsch, 2000; Robbins, 2001), is preferentially expressed in neurons having an important role in the control of local network oscillations in various CNS areas (Cooper et al. 2001).
Various channels potentially relevant to pacemaker activity are suggested to be expressed in cerebellar GoCs. mRNAs coding for the Ih channel subtype hcn2 (mouse; Santoro et al. 2000) and hcn2 protein (rat; Notomi & Shigemoto, 2004) were detected in the GL with a distribution compatible with their presence in GoCs. Transcripts coding for two members of the KCNQ family (KCNQ2 and KCNQ5; Wang et al. 1998; Schroeder et al. 2000; Saganich et al. 2001) were found in the rat GL, and selective expression of KCNQ2 protein was shown in putative mouse GoCs (Cooper et al. 2001). Finally, Iapa is mediated by channels of the SK family, in particular SK2 and SK3 subtypes (Kohler et al. 1996; Ishii et al. 1997). In rat GoCs, mRNAs encoding the SK3 subtype are particularly abundant (Stocker & Pedarzani, 2000). Overall, these data suggested that Ih, IM and Iapa could be functionally expressed in GoCs and could have a role in the control of spontaneous firing.
By performing loose cell-attached (LCA) and whole-cell (WC) recordings, we demonstrate that GoCs in acute cerebellar slices behave indeed as pacemaker neurons. Pacemaking involves the action of at least two depolarizing currents active in the subthreshold region (INa,sub and Ih) and possibly of an M-like current contributing to the repolarizing feedback. Iapa regulates spike after-hyperpolarization (AHP) and inter-spike interval (ISI) precision. These results bear several consequences for the mechanism of inhibition in the cerebellar circuit, and suggest that GoC pacemaking can be finely regulated by several voltage-dependent channels.
| Methods |
|---|
|
|
|---|
Sagittal or parasagittal cerebellar slices (220 µm thick) were cut from the vermis of 16- to 21-day-old (P16P21) Wistar rats, decapitated after deep anaesthesia with halothane (Sigma-Aldrich, Milan, Italy; 0·5 ml in 2 l administered for 12 min). All experiments were conducted in accordance with international guidelines from the European Community Council Directive 86/609/EEC on the ethical use of animals. During the slicing procedure, the cerebellar vermis was immersed in a cold (23°C) cutting solution containing (mM): potassium gluconate 130, KCl 15, ethylene glycol-bis (ß-aminoethyl ether) N,N,N',N'-tetraacetic acid (EGTA) 0.2, N-2-hydroxyethyl piperazine-N-2-ethanesulphonic acid (Hepes) 20, glucose 10, pH 7.4 with NaOH. This solution was found to improve the viability of GoCs (Dugué et al. 2005). Slices were incubated for at least 1 h before recordings in oxygenated bicarbonate-buffered (standard extracellular) saline maintained at 32°C, containing (mM): NaCl 120, KCl 2, MgSO4 1.2, NaHCO3 26, KH2PO4 1.2, CaCl2 2, glucose 11 (pH 7.4 when equilibrated with 95%O25%CO2).
Electrophysiological apparatus
For electrophysiological recordings, slices were transferred to the recording chamber and perfused at 1.5 ml min1 with oxygenated standard extracellular saline either at room temperature (RT; 2023°C) or at higher temperatures (3237°C), as indicated. Slices were visualized in an upright epifluorescence microscope (Axioskop 2 FS, Zeiss, Oberkochen, Germany) equipped with a x63, 0·9 NA water-immersion objective and differential interference contrast (DIC) optics, using infrared illumination (IR; excitation filter 750 nm) and an IR CCD camera (Till Photonics, Gräfelfing, Germany). Patch pipettes were fabricated from thick-walled borosilicate glass capillaries (1154150 or 1103286; Hilgenberg, Malsfeld, Germany) by means of a Sutter P-97 horizontal puller (Sutter Instruments, Novato, CA, USA). Recordings were obtained in the LCA or WC configuration, using a MultiClamp 700A (Axon Instruments, Molecular Devices, Sunnyvale, CA, USA) or, in a few cases, an Axoclamp 200B (Axon Instruments; in the IClamp Fast mode) amplifier. Images of cells filled with the fluorescent dye Alexa Fluor 488 (Molecular Probes, Invitrogen, S.Giuliano Milanese, Italy) were obtained using a 50 W Xe lamp (Zeiss), excitation and emission filters centred at 480 and 535 nm, and a 505 nm dichroic mirror (41001, Chroma Technology, Rockingham, VT, USA), a high-resolution digital camera (CoolSNAP HQ; Roper Scientific, Trenton, NJ, USA) and MetaMorph software (Universal Imaging Corporation, Downington, PA, USA).
Loose cell-attached recordings
For loose cell-attached (LCA) recordings (1050 M
seal resistance), patch pipettes contained the standard extracellular saline or, in a few cases, a Hepes-buffered extracellular saline (results were indistinguishable and were therefore pooled; 24 M
pipette resistance). Pipettes were held at 0 mV in the voltage-clamp mode. Consecutive 1 min current traces were filtered at 2 kHz and acquired at 50 kHz sampling rate. In these conditions, spikes in the recorded cell appear as biphasic, small (20200 pA peak-to-peak amplitude) current deflections (Fig. 1C). Recordings were judged to be stable when (i) the shape and amplitude of spikes was constant over time (Fig. 1C); and (ii) firing frequency was insensitive to changes in pipette holding potential. Stable recordings were routinely obtained for as long as 3040 min (Fig. 1C and D). Giga-seal cell-attached recordings were not suitable for this study, because they often showed partial transition to the WC configuration after a few minutes, as signalled by abrupt changes in spike waveform and frequency.
|
WC GoC recordings were performed with a potassium gluconate-based intracellular solution (KG) containing (mM): potassium gluconate 135 or 145, KCl 5, Hepes 10, EGTA 0.2, MgCl2 4.6, ATP-Na2 4, GTP-Na 0.4, pH 7.35 (supplemented with 100 µM Alexa Fluor 488 in a subset of recordings). The liquid junction potential (ELJ) between the bath and pipette solution was measured according to Neher (1992), and was 10 mV.
ELJ has been subtracted from membrane potential (Vm) measurements throughout the text. Pipettes had resistances of 34 M
and were coated with dental wax; seal resistance was 25 G
. Signals were filtered at 210 kHz and acquired at 1050 kHz. Recordings were only accepted for analysis if the basal current, when holding cells in voltage clamp at 70 mV, was positive to 100 pA. Pipette series resistance (Rs) was 25 ± 2 M
(n
= 74), and was constantly monitored during experiments; Rs compensation was not used. In current-clamp recordings, Vm measurements were corrected offline for errors introduced by Rs. An apparent input resistance was evaluated both in current-clamp and voltage-clamp conditions (RCC and RVC), as follows. In the current-clamp mode, RCC was measured, in cells maintained in a subthreshold regime (77/67 mV), as the chord of the Vmcurrent relation obtained from 1 s-long negative current injections which decreased Vm down to 84/72 mV (control experiments), or down to 111/123 mV (experiments with ZD 7288 application). In the voltage-clamp mode, RVC was measured from the current change at the end of 100 ms-long voltage-clamp steps from 70 to 80 mV (traces filtered at 10 kHz and acquired at 50 kHz). The input membrane capacitance Cm was approximately measured by subtracting the time-integral of steady-state current from the time-integral of total current developing during the same voltage-clamp step and dividing by the voltage jump. RVC and Cm measured immediately after break-in were 522 ± 332 M
(mean ±
S.D.; median value: 425 M
(n
= 45) and 146 ± 73 pF (mean ±
S.D.; n
= 45; see also Dieudonné, 1998). RVC gradually decreased during recordings (32 ± 4% in 1525 min, n
= 11 cells in control saline; see Fig. 3C). At the same time, cells were gradually depolarized, sometimes after an earlier hyperpolarizing phase. In a group of 14 cells (out of 26 analysed in detail) the membrane gradually hyperpolarized for several minutes after break-in (120 min; median 8 min), as seen from the change in current needed to maintain a Vm value of 70 mV (I70); from 27 ± 4 pA at < 1 min from break-in, to 13 ± 6 pA at the end of the hyperpolarizing period; n
= 14; P
= 0.0001, Wilcoxon matched-pairs test; see Fig. 3D); this hyperpolarizing phase was followed by slow progressive spontaneous depolarization (I70 was 33 ± 16 pA at 1822 min after break-in, n
= 9). In the remaining 12 cells, spontaneous depolarization was observed from the beginning of the WC recording. When averaging over both groups, I70 changed from 22 ± 6 pA to 41 ± 8 pA between 10 min and 20 min from break-in (n
= 21; P
= 0.008, Wilcoxon matched-pairs test).
|
All drugs were applied through the general bath perfusion, flowing at
1.5 ml min1, with a
1 min dead time before solution entrance in the bath. 4-Ethylphenylamino-1,2-dimethyl-6-methylaminopyrimidinium chloride (ZD 7288), D-()-2-amino-5-phosphonopentanoic acid (D-APV), 2,3-dioxo-6-nitro-1,2,3,4-tetrahydrobenzo[f]quinoxaline-7-sulphonamide disodium salt (NBQX), 6-imino-3-(4-methoxyphenyl)-1(6H)-pyridazinebutanoic acid hydrobromide (SR 95531), (3-aminopropyl)(diethoxymethyl)phosphinic acid (CGP35348) (all from Tocris) and strychnine (SIGMA) stocks were prepared in water. (S)-
-Methyl-4-carboxyphenylglycine ((S)-MCPG; Tocris) was dissolved at 10 mM in extracellular saline (glucose, CaCl2 and MgCl2 omitted). Apamin (Latoxan, Valence, France) stock was prepared in a Hepes-buffered saline (mM: NaCl 100, Hepes 20, pH 7.4 with NaOH). Tetrodotoxin (TTX; Latoxan) stocks were prepared in 0.1 M sodium citrate. N-(2-amino-4-(4-fluorobenzylamino)-phenyl) carbamic acid ethyl ester (retigabine) and 10,10-bis(4-pyridinylmethyl)-9(10H)-anthracenone (XE991) were kindly provided by Dr M. Taglialatela (University of Naples, Italy) and were dissolved in DMSO at 50 mM; a second XE991-dihydrochloride (Tocris) 10 mM stock solution was prepared in water, and no significant differences were observed between effects of the two stocks. All other chemicals were from Sigma-Aldrich.
Data analysis
For analysis, we used self-written routines in the IGOR environment (Wavemetrics, Lake Oswego, OR, USA). In LCA recordings, firing frequency (f) and variability of the interspike interval (ISI) were evaluated from the mean ISI and the ISI coefficient of variation (CVISI). CVISI was computed as the squared root of the ratio of ISI standard deviation to mean ISI. Each f and CVISI value was computed from an ISI sample collected over a time window of 1 min. LCA experiments were accepted for analysis of pharmacological effects on firing only when f change in a > 5 min control period preceding application of drugs was
10% (Fig. 1). Values used for the statistics of f and CVISI in control conditions and in the presence of synaptic blockers (see Results) were measured 13 min after seal formation and 35 min after application of blockers in each experiment.
In current-clamp recordings, properties of the action potential (AP) waveform were evaluated from the mean waveform, obtained by aligning 1030 APs at their peak (traces acquired at 2050 kHz sampling rate). Spike threshold (Vthr) was the Vm value where dVm/dt exceeded 5 mV ms1. Spike amplitude was the peak-threshold difference. Spike half-width was the time interval separating two successive crossings of 50% of spike amplitude during the rising and repolarizing AP phases. t1090 was the time required for Vm to rise from 10% to 90% of spike amplitude. Mean subthreshold Vm was calculated from a 1030 s trace, excluding values with Vm > Vthr. AHP trough was the minimum Vm value in the subthreshold interspike period; AHP rise was the time interval separating threshold crossing during spike repolarization and attainment of the AHP trough. Sag amplitude was the difference between minimum and steady-state Vm during a 1 s-long current step decreasing Vm down to 117.3 ± 1.3 mV (mean ± S.D.; range 123 to 111 mV; obtained with 150 to 350 pA; n = 8), either from a subthreshold regime (77/67 mV), or from the autorhythmic firing condition.
Statistics reported are mean ± standard error of the mean (S.E.M.) unless specified. Statistical non-parametric (for samples with n > 5) or parametric (for samples with n = 5) tests were performed using Instat (Graphpad Software, San Diego, CA, USA). Two-tailed P values were used throughout.
| Results |
|---|
|
|
|---|
In this paper we report an electrophysiological investigation covering 237 GoCs (181 cells recorded at room temperature (RT) and 56 cells at 3237°C) recorded in acute slices obtained from the rat cerebellum in the third postnatal week. GoCs were visually selected as cells presenting a large soma (> 10 µm diameter; Fig. 1A), located down to
20 µm below the surface of the GL in lobules IIVIII. We took care to avoid cells displaying the characteristic brush of unipolar brush cells (Mugnaini & Floris, 1994), or cells adjacent to the Purkinje cell layer and displaying a bipolar, fusiform soma shape, typical of Lugaro cells (Lugaro, 1894). Recent studies suggested that some Lugaro cells display a non-fusiform, multipolar soma morphology and are found at different levels in the GL (Geurts et al. 2001; Lainé & Axelrad, 2002). Therefore, besides visual selection, a further criterion is needed for GoC identification. In slices, Lugaro cells are in a resting state, and shift to rhythmic firing upon serotonin application (Dieudonné & Dumoulin, 2000). In order to exclude Lugaro cells, we limited analysis to cells displaying single-spike rhythmic firing in standard extracellular saline. This condition was met, at RT, in 87% of the cells (103 out of 120) studied with LCA recordings and by 81% (78 out of 96) of the cells studied with WC recordings. In the latter case, the presence of single-spike rhythmic firing was assessed in the cell-attached configuration prior to break-in or immediately thereafter. When maintaining slices at more physiological temperatures (3237°C), 80% of the visually selected large-soma interneurons (56 out of 70) displayed single-spike rhythmic firing. The remaining cells were either silent, with sporadic appearance of short spike sequences, or displayed bursting activity (not shown).
A subset of the visually selected cells subjected to WC recording (RT) was filled with the fluorescent dye Alexa Fluor 488 (100 µM). These cells displayed a dendritic arborization extending in both the granular and molecular layers. In 81% of cases (30/37 cells), the characteristic GoC axonal plexus with extended ramification into the GL (Golgi, 1883; Eccles et al. 1967) was observed (Fig. 1B). The remaining seven cells could have been GoCs with cut axon, or belonged to unrecognized different neuronal classes. Of the 30 cells endowed with a GoC-like axon, five were irregularly bursting or silent and were not analysed; as a consequence, the requirement for single-spike rhythmicity used in this study could have excluded a silent or bursting subpopulation of GoCs.
When recording with the LCA configuration (Fig. 1C), the firing frequency (f) of GoCs at RT was 3.0 ± 0.2 Hz (range 0.58.8 Hz, n = 103; Fig. 1E). In control conditions, firing continued for the entire length of recordings (up to 3040 min) with minimal changes of frequency and precision (Fig. 1C and D). The interspike interval (ISI) variability was measured by the coefficient of variation of the ISI (CVISI). CVISI median value at RT was 13.4% (n = 103; Fig. 1E), indicating that firing was highly regular in a large fraction of GoCs. CVISI was inversely correlated to firing frequency, being larger for lower frequencies (Spearman correlation coefficient: r = 0.6983, P < 0.0001; Fig. 1F). Firing frequency increased with temperature (Fig. 1E), being 4.2 ± 0.6 Hz at 3133°C (range 1.611.6 Hz, n = 17) and 9.3 ± 1.3 Hz at 3537°C (range 2.621.6 Hz, n = 24; P < 0.0001, non-parametric ANOVA), while the CVISI median value was relatively temperature insensitive, being 15% at 3133°C and 9.7% at 3537°C (Fig. 1E; P = 0.152, non-parametric ANOVA).
Spontaneous single-spike firing is an autorhythmic activity
GoCs receive excitatory NMDA and AMPA/kainate glutamatergic synaptic inputs (Dieudonné, 1998; Bureau et al. 2000; Misra et al. 2000) as well as glycinergic and GABAergic inhibitory synaptic inputs (Dieudonné, 1995; Dieudonné & Dumoulin, 2000), which may be spontaneously activated by recurrent activity in the slice preparation. Therefore, the ability to generate spontaneous rhythmic firing could depend on the activation of fast chemical synapses impinging onto GoCs. When addressing this issue in LCA recordings, we observed that firing was only slightly, although significantly, altered (Fig. 2A and B) upon bath application of a mixture of blockers of the above-mentioned ionotropic postsynaptic receptors (synaptic blockers; NBQX, 10 µM; D-APV, 25 µM; strychnine, 300 nM, and SR 95531 (gabazine), 30 µM). In fact, f was 3.6 ± 0.4 Hz with synaptic blockers and 3.9 ± 0.4 Hz in control (n = 20 cells; P = 0.024, Wilcoxon matched-pairs test; Fig. 2B), with a blockers/control frequency ratio of 0.92 ± 0.03. The effect of synaptic blockers developed in 23 min (Fig. 2A). Firing precision was not significantly influenced (CVISI in control: 11.9 ± 2.0%, CVISI with blockers: 10.9 ± 1.8%, n = 20 cells; P = 0.7285, Wilcoxon matched-pairs test; Fig. 2B), and in no case was firing blocked. This result shows that spontaneous rhythmic firing in GoCs does not depend on phasic input from afferent synapses, but rather is generated by intrinsic excitable mechanisms.
|
The rest of this work is devoted to uncovering the ionic mechanisms generating the pacemaker cycle in autorhythmic GoCs. We performed all subsequent experiments at RT in the presence of blockers of fast synaptic transmission (synaptic blockers, as above). We investigated the presence and role of several candidate currents including subthreshold Na+ currents, the hyperpolarization-activated cationic current (Ih), the M-type K+ current (IM) and the apamin-sensitive K+ current (Iapa).
Whole-cell recordings from Golgi cells
GoCs were further studied with the current-clamp WC configuration. When breaking into GoCs using potassium gluconate-based pipette solutions, spontaneous firing continued in 32 of 41 cells. In these cells, spike waveform exhibited rapid rise and decay (Table 1; Fig. 3A). The subthreshold interspike trajectory (pacemaker range; Table 1 and Fig. 3A) showed a pronounced AHP and spanned from
75 mV (AHP trough) to
55 mV (spike threshold). Comparison of firing frequency before and 12 min after membrane rupture (no injected current) showed a significant increase (gigaseal cell-attached, f: 3.2 ± 0.3 Hz; whole-cell, f: 4.6 ± 0.6 Hz; n
= 32 cells; P
= 0.048, Wilcoxon matched-pairs test). In 8 out of 16 cells (50%) in which spontaneous firing was continuously monitored, f decreased, and eventually firing stopped within a few minutes after membrane rupture (Fig. 3B). In all cases, the apparent input resistance (measured in voltage clamp, RVC; see Methods and Fig. 3C) and the current needed to maintain Vm at 70 mV (measured in current clamp, I70; see Methods and Fig. 3D) showed progressive changes after break-in. These effects, which are possibly linked to cytoplasmic dialysis and/or increasing leak conductance through the seal, are likely to perturb the delicate balance of small ionic currents active in the subthreshold region. Therefore, in order to study the impact of pharmacological block of ionic currents on spontaneous firing, we took advantage of the LCA configuration, which, as reported above, permits long stable recordings of firing activity. WC recordings provided useful information on some functional parameters which were stable enough during several tens of minutes. These were, in current-clamp recordings, the firing frequency-to-injected current (fI) relationship (see below and Fig. 3F) and the extent of inward rectification at negative potentials (Fig. 5); in voltage-clamp recordings, the amplitude of subthreshold persistent Na+ current (Fig. 4).
|
|
|
200 Hz (n
= 6 cells; holding current 0 pA; 39 Hz basal firing frequency; Fig. 3G). Spike frequency adaptation at the end of depolarizing steps (measured as 1 (f1s/fin), where f1s is instantaneous frequency estimated at the end of the step) was modest (11 ± 3%) for fin in the 735 Hz range, and increased to 74 ± 12% for fin in the 200210 Hz range (Fig. 3H; see also Fig. 3 in Dieudonné, 1998). Thus GoCs can generate repetitive firing upon a large range of depolarizing input intensities. At the end of discharge in response to depolarizing pulses, GoCs showed a marked AHP which delayed the re-establishment of pacemaker activity (Fig. 3E). The AHP depth and duration increased with stimulation intensity.
Subthreshold Na+ current
Na+ currents active in the subthreshold range (INa,sub) have been implicated in the generation and regulation of pacemaker activity in several neuronal types (see Introduction). The effects of TTX block of subthreshold and suprathreshold Na+ currents cannot be separated while observing occurrence of spikes with LCA recordings; therefore we could not directly verify the functional effect of INa,sub in spontaneous firing. Indirect information can nevertheless be obtained by measurement of INa,sub during somatic GoC voltage clamp in a restricted voltage range (70 to 60 mV), where artefacts due to axial current flow arising from imperfect space clamp and to series resistance are minimized (White et al. 1995). We examined responses to 2 s-long voltage steps from a holding potential of 70 mV up to 60 mV before and after TTX application (500 nM; Fig. 4A). Subtraction of average traces obtained from control periods and after reaching steady-state TTX block revealed a TTX-sensitive steady inward current (Fig. 4A and B), activating positive to 70 mV (Fig. 4C), which had an amplitude of 23 ± 5 pA at the end of a step to 60 mV (n
= 5; Fig. 4D). This indicates that INa,sub is active in GoCs at voltages positive to 70 mV, and therefore should take part in the slow pacemaker depolarization leading to spike threshold. Moreover, the current remaining after TTX block at command voltages positive to 60 mV was outward at all times during the step (n
= 4 out of 5 cells); given that spike threshold in GoCs is
55 mV (Table 1), this suggests that the TTX-sensitive current is necessary to drive GoC pacemaking.
Hyperpolarization-activated current (Ih)
A Cs+-sensitive inward rectification of GoC membrane current at negative voltages has been shown in the rat by Dieudonné (1998) and in the turtle by Midtgaard (1992), suggesting the presence of an Ih current. To confirm the presence of inwardly rectifying currents in GoCs in current-clamp recordings, we examined responses to 1 s-long negative current steps from cells maintained in a subthreshold regime (77/67 mV) by means of negative steady current injection. At 721 min from break-in, responses showed a characteristic, stable, slowly developing voltage sag, suggesting the slow opening of Ih channels (Fig. 5A). Consistently, at the end of hyperpolarizing current injection, a transient after-depolarization indicated the delayed deactivation of Ih channels activated at negative potential (Fig. 5A). Return from hyperpolarization into the firing region was often associated with a short spike burst (not shown).
GoC apparent input resistance (RCC; see Methods) significantly decreased during the step (at the time of Vm minimum: 340 ± 44 M
; after 1 s: 244 ± 32 M
; n
= 8 cells; Fig. 5B). The voltage sag amplitude, for negative current steps hyperpolarizing Vm down to 117 ± 1 mV, was 11.4 ± 1.9 mV (n
= 8; Fig. 5A). In six cells, inward rectification was largely reduced by perfusing slices with the bradicardic agent ZD 7288 (20 µM), a potent (IC50 for Ih block in brain slices: 10.5 µM, Gasparini & DiFrancesco, 1997; 2.3 µM, Neuhoff et al. 2002) and selective Ih blocker (e.g. Dickson et al. 2000; but see Do & Bean, 2003) (Fig. 5C). Peak and steady-state RCC were increased by 44 ± 7% and 81 ± 17% by the drug (from 266 ± 23 to 379 ± 33 M
, P
= 0.031, peak RCC; from 193 ± 26 to 333 ± 32 M
, P
= 0.031, steady-state RCC; Wilcoxon matched-pairs tests; n
= 6 cells), indicating the presence of a ZD 7288-blocked current which developed along the step (Fig. 5D). The Vm sag decreased by 51 ± 5% after 812 min drug application (from 12.9 ± 3.0 mV to 6.1 ± 1.4 mV, n
= 6, P
= 0.031, Wilcoxon matched-pairs test; Fig. 5C). These data indicate that slow inward rectification was sustained by activation of Ih, and further confirm that a robust Ih current is present in GoCs.
We investigated the role of Ih in GoC pacemaking by studying firing properties in LCA recordings before and after slice perfusion with ZD 7288 (20 µM). The onset of the ZD 7288 effect on firing frequency was slow, starting 512 min after application, and led to slow progressive f decrease (Fig. 6A and B; n
= 7 cells): 10 min after the start of the ZD 7288 effect, f had decreased on average by
59%, from 3.9 ± 0.8 Hz (range 2.78.5 Hz) in control to 1.4 ± 0.2 Hz (range 0.752.1 Hz) (P
= 0.016, Wilcoxon matched-pairs test; Fig. 6C). In parallel with frequency, firing precision also decreased (Fig. 6A and B), with CVISI increasing from 10.4 ± 2.6% to 26.4 ± 7.6% (control vs ZD 7288; P
= 0.016, Wilcoxon matched-pairs test; 10 min after application; Fig. 6C). This early effect was followed, in three of seven cells, by a progressive clustering of spikes, appearing 1020 min after drug application and sometimes ending in a clear bursting behaviour (not shown). The initial frequency decrease and the associated CV increase can be explained by a decrease of an inward current contributing to subthreshold pacemaker depolarization; it is therefore consistent with Ih block as the mechanism mediating the early effect of ZD 7288.
|
Do & Bean (2003) reported inconsistent effects of ZD 7288 on firing in subthalamic nucleus neurons, proposed to arise from non-specific blocking effects. They show that ZD 7288 (10 µM) blocks an outward, hyperpolarizing current developing while the membrane potential trajectory spans the subthreshold pacemaker range; this is paralleled, in current-clamp recordings, by membrane depolarization, firing frequency increase and, in some cells, by depolarization block of firing. In all GoC LCA recordings, f did gradually decrease over 1020 min during ZD 7288 application, without ever accelerating or stopping. This is in contrast to the effects expected from progressive depolarization that should lead to f increase and eventually to abrupt firing arrest, thus ruling out the possibility that the effect of ZD 7288 on GoC firing is caused by block of outward currents. In conclusion, our data show that a ZD 7288-sensitive Ih current has an important role in sustaining GoC pacemaker activity.
Retigabine-sensitive M-type K+ currents
Neuronal K+ currents active in the subthreshold voltage range generate hyperpolarizing current counteracting slow pacemaker depolarization and contributing to the determination of the interspike interval duration. A number of functional K+ current types may in principle contribute to subthreshold repolarizing current. Besides the delayed-rectifier-type and BK-type Ca2+- and voltage-dependent K+ currents, which activate during or immediately following the spike and deactivate fast after repolarization, candidate K+ currents include slowly activating M-like, transient outward A-type and SK-type Ca2+-dependent K+ currents, together with voltage-independent leak channels. We initiate the analysis of K+ currents contributing to the determination of the pacemaker rhythm in GoCs by focusing on retigabine-sensitive M-like K+ currents and apamin-sensitive SK-type Ca2+-dependent K+ currents.
Among the available pharmacological tools for the study of the M-type K+ current IM is the cognition-enhancing drug XE991, which blocks heterologously expressed neuronal KCNQ channels (KCNQ25) with variable potency depending on the specific subunit combination (Wang et al. 1998; Robbins, 2001) and is a potent IM blocker in intact neurons (IC50 < 1 µM; Wang et al. 1998; Oliver et al. 2003; Passmore et al. 2003; Romero et al. 2004). The anticonvulsant drug retigabine increases IM in heterologously expressed channels formed with KCNQ25 subunits (Main et al. 2000; Rundfeldt & Netzer, 2000; Tatulian et al. 2001; Wickenden et al. 2001) and increases IM in intact cells (Wickenden et al. 2000; Tatulian et al. 2001).
In order to gain information on the presence of functional KCNQ channels in GoCs, we studied the effect of bath perfusion of retigabine on cellular responses recorded during current-clamp whole-cell experiments. We injected 1 s-long depolarizing current steps in cells steadily hyperpolarized to 70 mV by current injection. Application of retigabine (5 µM) led, in a few minutes, to a clear excitability decrease, as measured from the decreased number of spikes evoked by a fixed-amplitude step. With steps of 90 or 100 pA, this number (N90100) was 12.1 ± 1.6 in control, and 6.2 ± 2.6 after 717 min in retigabine, corresponding to a 52 ± 16% decrease (n = 5; Fig. 7AC). The decrease in N90100 after retigabine was significantly larger (P = 0.002, Mann-Whitney test) than spontaneous rundown in comparable time windows of control recordings (see Fig. 3F, legend). These results show that retigabine depresses cell excitability, and this is likely to be mediated by recruitment of functional KCNQ channels.
|
10 min from break-in, and 17 ± 14.5 pA after 717 min in retigabine, i.e. 717 min later (n
= 5). This I70 change is significantly different (P
= 0.029, Mann-Whitney test) from the change observed in the same time window in control recordings, where I70 became more negative with time (see Methods and Fig. 3D). These observations are thus compatible with a hyperpolarizing effect of retigabine. The apparent input resistance measured in voltage clamp in the 70/80 mV range decreased during recordings, before and after retigabine application (not shown), in a way similar to that observed in control whole-cell recordings (Fig. 3C), suggesting that the membrane conductance increase associated with the WC configuration masks the increase due to enhanced retigabine-mediated opening of KCNQ channels. To investigate the role of KCNQ channels in GoC autorhythmic activity, we sought a selective antagonist rather than an agonist. We monitored firing properties in LCA recordings during bath application of XE991 (5 µM). After 10 min of continuous application, firing frequency f and CVISI were not significantly different from control (mean f in control: 3.21 ± 0.73 Hz; after XE991: 3.31 ± 0.81 Hz; n = 5 cells; P = 0.589; mean CVISI in control: 12 ± 5%; after XE991: 10 ± 4%; n = 5 cells; P = 0.125; paired t tests; Fig. 8); further drug application for 510 min gave similar results (not shown). Two different XE991 stock solutions were used for this purpose (see Methods), with indistinguishable results. Therefore, we have no evidence for a contribution of XE991-sensitive KCNQ channels to the regulation of pacemaker activity in GoCs.
|
Apamin-sensitive Ca2+-dependent K+ currents
In several neuronal types, apamin-sensitive SK channel-mediated Ca2+-dependent K+ currents, Iapa, are involved in the generation of the AHP that develops after a single spike in the 10100 ms time range (single-spike AHP or mAHP; reviewed in Stocker, 2004). To verify the presence of functional SK-type channels in GoCs, we studied the effect of the specific blocker apamin (50 nM; reported IC50 for SK3 channels is 0.64 nM; reviewed in Stocker, 2004) on the single-spike AHP in whole-cell current-clamp recordings. After 24 min bath application, apamin decreased the AHP trough observed in spontaneously firing cells (n = 5; control: 68.8 ± 2.6 mV; after 24 min in apamin: 63.6 ± 2.9 mV; P = 0.026, paired t test; Fig. 9A), indicating that Iapa was contributing to the generation of the AHP. A clear apamin-induced decrease of the single-spike AHP amplitude was also observed in cells maintained at 70 mV with negative current injection and briefly (0.5 ms) stimulated with just-threshold current steps to evoke single spikes (not shown).
|
| Discussion |
|---|
|
|
|---|
It should be noted that some neurons in vivo can switch between non-pacemaker and pacemaker properties in relation to behavioural requirements, as reported for neurons in the mammalian respiratory network, hypothalamus and basal ganglia and for crustacean neurons (reviewed in Ramirez et al. 2004; Surmeier et al. 2005). Neuromodulators play an important part in the induction, enhancement and suppression of pacemaker properties: through multiple channel modulations, excitability is increased or decreased, pushing a cell into the firing regime or away from it. Relevant neuromodulatory effects may also occur in slices in relation to accumulation or depletion of transmitters. However, GoC firing in our experiments was resistant to block of group I/group II mGluRs and GABAB receptors, showing that periodic activity was not due to depolarization arising after activation of these receptors by ambient glutamate and GABA. While there might still be modulatory agents influencing pacemaking (e.g. acetylcholine, noradrenaline, or serotonin), an indication that slice conditions were compatible with those occurring in vivo comes from the observation that Golgi cells in vivo and in vitro fire rhythmically at similar frequencies.
GoC spontaneous firing frequency at physiological temperature (
9 Hz on average) was slightly lower or similar to values measured in the rat in vivo (
15 Hz, Schulman & Bloom, 1981;
8.4 Hz, Vos et al. 1999). Firing was much more regular in slices (CVISI
0.1) than in vivo (CVISI
0.9, Vos et al. 1999). The frequency and regularity of GoC activity in vivo is likely to be influenced by massive synaptic inputs, which are absent in slices because granule cells do not discharge spontaneously (D'Angelo et al. 1995) and afferent mossy fibres are deprived of their cell body. Accordingly, firing activity in slices was marginally altered by block of such inputs. Firing frequency and regularity were correlated, and were modulated in parallel by downregulation of intrinsic currents relevant to pacemaking (with the exception of Iapa; see below). Firing regularity in vivo should thus be under dual control of synaptic inputs and the level of activity of pacemaker channels.
Because of their rhythmic firing at 110 Hz and the extended plexiform axonal arborization developing in the granular layer, the majority (8187%) of large neurons in lobules IIVIII were identified as Golgi cells. It should be recalled that Lugaro cells, which might in some cases display a GoC-like soma located deep in the GL (Lainé & Axelrad, 2002), do not discharge spontaneously in slice preparations (Dieudonné & Dumoulin, 2000). The main electrophysiological properties of GoCs were homogeneous. However, we cannot rule out that a minority of large granular layer interneurons, excluded from this study because silent, irregularly firing or bursting, represent functionally different GoC subtypes; indeed, a few non-pacemaker neurons endowed with a Golgi-like plexiform axon were observed. The existence of GoC subtypes has been previously suggested on the basis of neurochemical studies (Geurts et al. 2001). The observation that, in a small fraction of cells characterized by low discharge frequency, apamin was ineffective on pacemaking, might also indicate the existence of distinct functional GoC subclasses.
In addition to autorhythmicity, which is the focus of the present study, GoCs revealed interesting dynamic behaviours, including the ability to (i) respond to a depolarizing input with high-frequency repetitive firing up to 200 Hz showing adaptation at increasing frequencies; and (ii) to produce a deep AHP following discharge. These properties match behaviours of GoCs in vivo, which can show sustained discharge at high frequency (up to 50 Hz, Edgley & Lidierth, 1987; 20150 Hz, Miles et al. 1980). Following punctuate sensory stimulation, GoCs respond with short bursts of 23 spikes at up to 200300 Hz followed by a silent pause (Vos et al. 1999), which can therefore be due, at least in part, to intrinsic GoC electroresponsive properties. The presence of spike-frequency adaptation, together with rebound excitation following a hyperpolarization, suggests that GoCs are able to signal the time of input changes both in the excitatory and inhibitory direction; rebound excitation following hyperpolarization may contribute to resetting the phase of spontaneous firing (Chan et al. 2004).
Membrane currents underlying Golgi cell autorhythmic firing
While looking for depolarizing current components contributing to the pacemaker depolarization in GoCs, we found evidence for the participation of Na+ currents and Ih.
Subthreshold Na+ current. A non-inactivating subthreshold Na+ current is active in GoCs in the pacemaker range (positive to 70 mV), as shown here by the effect of TTX on the steady-state current measured with small voltage-clamp steps. A persistent Na+ current of similar amplitude has been recorded recently in rat GoCs (J. Magistretti, unpublished results). This current is likely to play a critical role in driving autorhythmic firing, thus adding to the emerging evidence that Na+ currents are major sources for the depolarizing drive to threshold in low-frequency rhythmic neurons (Pennartz et al. 1997; Feigenspan et al. 1998; Bevan & Wilson, 1999; Bennett et al. 2000; Beurrier et al. 2000; Taddese & Bean, 2002; Do & Bean, 2003; Jackson et al. 2004; see also Wilson & Callaway, 2000).
Hyperpolarization-activated cationic current Ih. The decrease of firing frequency induced in GoCs by ZD 7288 suggests that Ih contributes to the subthreshold pacemaker depolarization, as found in other low-frequency pacemaker neurons (Maccaferri & McBain, 1996; Bennett et al. 2000; Neuhoff et al. 2002; Funahashi et al. 2003; Chan et al. 2004). The hypothesis that the effect of ZD 7288 on firing is mediated by block of hyperpolarizing K+ conductances (Do & Bean, 2003) is ruled out in GoCs by the slow, gradual firing deceleration and the lack of firing arrest. Ih was reported not to be involved in firing in some pacemaker neuronal types (Pennartz et al. 1997; Feigenspan et al. 1998; Bevan & Wilson, 1999; Taddese & Bean, 2002; Do & Bean, 2003; but see Beurrier et al. 2000), suggesting that in those neurons a relatively negative activation threshold prevents current build-up in the interspike voltage range. However, Ih activation threshold and half-activation potential are variable across cell types (Pape, 1996). Given the role of Ih in GoC pacemaking, its activation threshold in these neurons should be relatively positive.
M-type K+ current. We showed that GoC excitability is decreased by application of low doses (5 µM) of the anticonvulsant drug retigabine. At this dose, retigabine is an agonist at recombinant homomeric and heteromeric channels formed with KCNQ25 (Main et al. 2000; Wickenden et al. 2000; Tatulian et al. 2001; Dupuis et al. 2002) and increases native IM in sympathetic neurons (Wickenden et al. 2000; Tatulian et al. 2001; Passmore et al. 2003). Low retigabine doses are ineffective on Na+ and Ca2+ currents (Rundfeldt & Netzer, 2000). A potentiation of GABAA receptor activity has been reported (Rundfeldt & Netzer, 2000); however, the latter should not significantly influence the effect in GoCs reported here, which was obtained in the presence of saturating doses of the GABAA antagonist gabazine. Thus the observed retigabine effect argues in favour of the functional presence of a retigabine-sensitive, KCNQ-mediated M-type current in GoCs.
We also show that low doses (5 µM) of the IM antagonist XE991 have no effect on pacemaking. This was unexpected given the suggested presence of IM in GoCs. It was reported that XE991 block is voltage dependent in sympathetic neurons (Romero et al. 2004), being more effective at positive (30 mV) potentials. However, effects of XE991 on cells maintained in resting, hyperpolarized conditions have also been reported (Yu & Yaari, 2004; Gu et al. 2005). It is therefore questionable whether the lack of effect of XE991 on spontaneous firing in GoCs is due to voltage dependence of IM block. The phenomenon could alternatively be explained if the suggested retigabine-sensitive current was XE991 insensitive and/or was not involved in control of autorhythmic firing properties. The latter hypothesis seems unlikely given that the current is involved in control of threshold excitability (Fig. 7). As a consequence, we hypothesize that the retigabine-sensitive current in GoCs is not sensitive to low XE991 doses. This raises the problem of the molecular identity of such current. The precise molecular profile of KCNQ-containing retigabine targets in GoCs is unknown, and their XE991 sensitivity might be influenced by coassembled accessory subunits. KCNQ5 mRNA is present in the rat GL (Schroeder et al. 2000), and KCNQ5 homomeric recombinant channels are reported to have low sensitivity to XE991 block (Schroeder et al. 2000). Further studies including direct recording of retigabine-sensitive current will be necessary to clarify these subjects.
SK-type Ca2+-dependent K+ currents. Apamin disrupted firing regularity, showing that apamin-sensitive Ca2+-dependent K+ channels from the SK family are essential for generating highly precise pacemaking in GoCs. This is similar to observations in other low-frequency pacemaker neurons (Shepard & Bunney, 1988; reviewed in Stocker, 2004). Saturating apamin doses for SK channels did not significantly alter the average firing frequency, in line with o