|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
University College London, Tissue Repair and Engineering Centre, Institute of Orthopaedics and Musculoskeletal Science, RNOH Campus, Brockley Hill, Stanmore HA7 4LP, UK
This study aimed to investigate the preferential collagen fibril alignment in unloaded and loaded tendons using elastic scattering spectroscopy. The device consisted of an optical probe, a pulsed light source (320860 nm), a spectrometer and a PC. Two probes with either 2.75 mm or 300 µm source-detector separations were used to monitor deep and superficial layers, respectively. Equine superficial digital flexor tendons were subjected to ex vivo progressive tensional loading. Seven times more backscattered light was detected parallel rather than perpendicular to the tendon axis with the 2.75 mm separation probe in unloaded tendons. In contrast, using the 300 µm separation probe the plane of maximum backscatter (3-fold greater) was perpendicular to the tendon axis. There was no optical anisotropy in the cross-sectional plane of the tendon (i.e. the transversely cut tendon surface), with no structural anisotropy. During mechanical loading (914% strain) backscatter anisotropy increased 8.5- to 18.5-fold along the principal strain axis for 2.75 mm probe separation, but almost disappeared in the perpendicular plane (measured using the 300 µm probe separation). Optical (anisotropy) and mechanical (strain) measurements were highly correlated. We conclude that spatial anisotropy of backscattered light can be used for quantitative monitoring of collagen fibril alignment and tissue reorganization during loading, with the potential for minimally invasive real-time structural monitoring of fibrous tissues in normal, pathological or repairing tissues and in tissue engineering.
(Received 11 September 2003;
accepted after revision 23 October 2003;
first published online 24 October 2003)
Corresponding author O. Kostyuk: University College London, Tissue Repair and Engineering Centre, Institute of Orthopaedics and Musculoskeletal Science, RNOH Campus, Brockley Hill, Stanmore HA7 4LP, UK. Email: rehkrab{at}ucl.ac.uk
This article has been cited by other articles:
![]() |
O. Kostyuk and R. A. Brown Novel Spectroscopic Technique for In Situ Monitoring of Collagen Fibril Alignment in Gels Biophys. J., July 1, 2004; 87(1): 648 - 655. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |